<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">nuc</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник НЯЦ РК</journal-title><trans-title-group xml:lang="en"><trans-title>NNC RK Bulletin</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1729-7516</issn><issn pub-type="epub">1729-7885</issn><publisher><publisher-name>Национальный ядерный центр Республики Казахстан</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.52676/1729-7885-2018-1-44-48</article-id><article-id custom-type="elpub" pub-id-type="custom">nuc-73</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>СТЕПЕНЬ ВЛИЯНИЯ ИЗЛУЧЕНИЯ МОБИЛЬНЫХ ТЕЛЕФОНОВ НА КАЧЕСТВО ЭПР СПЕКТРОВ</article-title><trans-title-group xml:lang="en"><trans-title>THE DEGREE OF INFLUENCE RADIATION FROM MOBILE PHONES ON THE QUALITY OF EPR SPECTRA</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Жумадилов</surname><given-names>К. Ш.</given-names></name><name name-style="western" xml:lang="en"><surname>Zhumadilov</surname><given-names>K. Sh.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Aстана</p></bio><bio xml:lang="en"><p>Astana</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Иванников</surname><given-names>А. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Ivannikov</surname><given-names>A. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Обнинск</p></bio><bio xml:lang="en"><p>Obninsk</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Абышев</surname><given-names>Б. К.</given-names></name><name name-style="western" xml:lang="en"><surname>Abyshev</surname><given-names>B. K.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Aстана</p></bio><bio xml:lang="en"><p>Astana</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Степаненко</surname><given-names>В. Ф.</given-names></name><name name-style="western" xml:lang="en"><surname>Stepanenko</surname><given-names>V. F.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Обнинск</p></bio><bio xml:lang="en"><p>Obninsk</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Хоши</surname><given-names>М.</given-names></name><name name-style="western" xml:lang="en"><surname>Hoshi</surname><given-names>M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Хиросима</p></bio><bio xml:lang="en"><p>Hiroshima</p></bio><xref ref-type="aff" rid="aff-3"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru">Евразийский Национальный университет им. Л.Н. Гумилева<country>Казахстан</country></aff><aff xml:lang="en">L.N. Gumilyov Eurasian National University<country>Kazakhstan</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru">МРНЦ им. А.Ф. Цыба – филиал ФГБУ «НМИРЦ» Минздрава России<country>Россия</country></aff><aff xml:lang="en">MRRC named after A.F. Tsyba – a branch of the FSBI «NMRCR» of the Ministry of Health<country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru">Университет Хиросимы<country>Япония</country></aff><aff xml:lang="en">Hiroshima University<country>Japan</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>30</day><month>03</month><year>2018</year></pub-date><volume>0</volume><issue>1</issue><fpage>44</fpage><lpage>48</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Жумадилов К.Ш., Иванников А.И., Абышев Б.К., Степаненко В.Ф., Хоши М., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Жумадилов К.Ш., Иванников А.И., Абышев Б.К., Степаненко В.Ф., Хоши М.</copyright-holder><copyright-holder xml:lang="en">Zhumadilov K.S., Ivannikov A.I., Abyshev B.K., Stepanenko V.F., Hoshi M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journals.nnc.kz/jour/article/view/73">https://journals.nnc.kz/jour/article/view/73</self-uri><abstract><p>В статье приведены результаты исследования степени влияния излучения мобильных телефонов на формирование спектров электронного парамагнитного резонанса (ЭПР) и электромагнитного шума на примере измерений образцов зубных эмалей для диапазона низких доз. С этой целью были получены спектры облученных зубных образцов. Спектры десяти образцов, облученных в номинальных дозах 0, 100, 200, 300 и 500 мГр парами, регистрировались в разное время с мобильным телефоном, и без него. Мобильный телефон был расположен вблизи резонатора спектрометра ЭПР. Специальное программное обеспечение применялось для извлечения радиационно-индуцированного сигнала (РИС) из полного спектра ЭПР и определения его интенсивности. Как было упомянуто выше, для изучения влияния сигнала мобильного телефона на сигнал ЭПР в этом исследовании, радиационный сигнал (RIS) (стандартное отклонение (SD)) будет оцениваться фоновым сигналом и остаточной суммой. Эти параметры были получены для одиночных измерений и как среднее для четырех повторных измерений.</p></abstract><trans-abstract xml:lang="en"><p>The results of the investigation of the effect of mobile phone radiation on the formation of electron paramagnetic resonance (EPR) spectra and electromagnetic noise on the example of measurements of dental enamel samples for the low dose range are presented. To this end, spectra of irradiated dental samples were obtained. The spectra of ten samples irradiated in nominal doses of 0, 100, 200, 300 and 500 mGy in pairs were registered at different times with and without a mobile phone. The mobile phone was located near the resonator of the EPR spectrometer. Specially software was used to extract the radiation-induced signal (RIS) from the full EPR spectrum and determine its intensity. As mentioned above to study the effect of the mobile phone signal on the EPR signal in this study, the radiation signal (RIS) (standard deviation (SD)) will be estimated by the background signal and the residual amount. These parameters were obtained for single measurements and, on average, for four repeated measurements.</p></trans-abstract><funding-group xml:lang="ru"><funding-statement>Авторы статьи выражают искреннюю благодарность за финансовую поддержку из средств Министерства образования и науки Республики Казахстан (на 2018–2020 гг. по грантовому финансирования субъектов научной и/или научно-технической деятельности по проекту ИРН АР05135470).</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Pozar, David M. Microwave Engineering Addison-Wesley Publishing Company. ISBN 0-201-50418-9). - 1993.</mixed-citation><mixed-citation xml:lang="en">Pozar, David M. Microwave Engineering Addison-Wesley Publishing Company. ISBN 0-201-50418-9). - 1993.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Comparison of mobile phone standards.http://en.wikipedia.org/wiki/. - 2011.</mixed-citation><mixed-citation xml:lang="en">Comparison of mobile phone standards.http://en.wikipedia.org/wiki/. - 2011.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Poole C.P. Electron spin resonance: comprehensive treatise on experimental techniques. - 2nd edition. Wiley, New York - 1983.</mixed-citation><mixed-citation xml:lang="en">Poole C.P. Electron spin resonance: comprehensive treatise on experimental techniques. - 2nd edition. Wiley, New York - 1983.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Ivannikov A.I. et al. Individual dose reconstruction among residents living in the vicinity of the Semipalatinsk Nuclear Test Site using EPR spectroscopy of tooth enamel // Health Phys. - 2002. - Vol. 83. - P. 183-196.</mixed-citation><mixed-citation xml:lang="en">Ivannikov A.I. et al. Individual dose reconstruction among residents living in the vicinity of the Semipalatinsk Nuclear Test Site using EPR spectroscopy of tooth enamel // Health Phys. - 2002. - Vol. 83. - P. 183-196.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Ivannikov A.I. et al. Dental enamel EPR dosimetry: comparative testing of the spectra processing methods for determination of Radiation induced-signal amplitude // Health Phys. - 2010. - Vol. 98. - P. 345-351.</mixed-citation><mixed-citation xml:lang="en">Ivannikov A.I. et al. Dental enamel EPR dosimetry: comparative testing of the spectra processing methods for determination of Radiation induced-signal amplitude // Health Phys. - 2010. - Vol. 98. - P. 345-351.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Tielewuhan E. et al. Spectra processing at tooth enamel dosimetry: analytical description of EPR spectrum at different microwave power // Radiat. Meas. - 2006. - Vol. 41. - P. 410–417.</mixed-citation><mixed-citation xml:lang="en">Tielewuhan E. et al. Spectra processing at tooth enamel dosimetry: analytical description of EPR spectrum at different microwave power // Radiat. Meas. - 2006. - Vol. 41. - P. 410–417.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Zhumadilov K. et al. ESR dosimetry study on population of settlements nearby Ust-Kamenogorsk city, Kazakhstan // Radiat. Environ. Biophys. - 2009. - Vol. 48. - P. 419–425.</mixed-citation><mixed-citation xml:lang="en">Zhumadilov K. et al. ESR dosimetry study on population of settlements nearby Ust-Kamenogorsk city, Kazakhstan // Radiat. Environ. Biophys. - 2009. - Vol. 48. - P. 419–425.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">IAEA Report. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. Report of a coordinated research project // IAEA-TecDoc-1331. - Vienna. - 2002.</mixed-citation><mixed-citation xml:lang="en">IAEA Report. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. Report of a coordinated research project // IAEA-TecDoc-1331. - Vienna. - 2002.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Hoshi M. et al. Interlaboratory comparison of tooth enamel dosimetry on Semipalatinsk region: Part 1, general view //Radiat. Meas. - 2007. - Vol. 42. - P. 1005-1014.</mixed-citation><mixed-citation xml:lang="en">Hoshi M. et al. Interlaboratory comparison of tooth enamel dosimetry on Semipalatinsk region: Part 1, general view //Radiat. Meas. - 2007. - Vol. 42. - P. 1005-1014.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Ivannikov A.I. et al. Interlaboratory comparison of tooth enamel dosimetry on Semipalatinsk region: Part 2, Effects of spectrum processing // Radiat. Meas. - 2007. - Vol. 42. - P. 1015-1020.</mixed-citation><mixed-citation xml:lang="en">Ivannikov A.I. et al. Interlaboratory comparison of tooth enamel dosimetry on Semipalatinsk region: Part 2, Effects of spectrum processing // Radiat. Meas. - 2007. - Vol. 42. - P. 1015-1020.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Ivannikov A.I. et al. EPR Tooth Enamel Dosimetry: Optimization of the Automatic Spectra Deconvolution Procedure // Health Phys. - 2001. - Vol. 81(2). - P. 124-137.</mixed-citation><mixed-citation xml:lang="en">Ivannikov A.I. et al. EPR Tooth Enamel Dosimetry: Optimization of the Automatic Spectra Deconvolution Procedure // Health Phys. - 2001. - Vol. 81(2). - P. 124-137.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Ivannikov A.I. et al. Optimization of recording conditions for the electron paramagnetic resonance signal used in dental enamel dosimetry // Radiat. Prot. Dosim. - 2002. -Vol. 100. - P. 531-538.</mixed-citation><mixed-citation xml:lang="en">Ivannikov A.I. et al. Optimization of recording conditions for the electron paramagnetic resonance signal used in dental enamel dosimetry // Radiat. Prot. Dosim. - 2002. -Vol. 100. - P. 531-538.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Zhumadilov K.S. et al. Tooth enamel EPR dosimetry: selecting optimal spectra registration parameters and effects of sample mass on sensitivity // J. Radiat. Res. - 2005. - Vol. 46. - P. 435-442.</mixed-citation><mixed-citation xml:lang="en">Zhumadilov K.S. et al. Tooth enamel EPR dosimetry: selecting optimal spectra registration parameters and effects of sample mass on sensitivity // J. Radiat. Res. - 2005. - Vol. 46. - P. 435-442.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Tanaka K. et al. Study on influence of X-ray baggage scan on ESR dosimetry for SNTS using human tooth enamel //J. Radiat. Res. - 2006. - Vol. 46. - P. 435-442.</mixed-citation><mixed-citation xml:lang="en">Tanaka K. et al. Study on influence of X-ray baggage scan on ESR dosimetry for SNTS using human tooth enamel //J. Radiat. Res. - 2006. - Vol. 46. - P. 435-442.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Zhumadilov K. et al. Results of tooth enamel EPR dosimetry for population living in the vicinity of the Semipalatinsk nuclear test site // Radiat. Meas. - 2007. - Vol. 42. - P. 1049-1052.</mixed-citation><mixed-citation xml:lang="en">Zhumadilov K. et al. Results of tooth enamel EPR dosimetry for population living in the vicinity of the Semipalatinsk nuclear test site // Radiat. Meas. - 2007. - Vol. 42. - P. 1049-1052.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Zhumadilov K. et al. Measurement of absorbed doses from X-ray baggage examinations to tooth enamel by means of ESR and glass dosimetry //Radiat. Environ.Biophys. - 2008. - Vol. 47. P. 541-545.</mixed-citation><mixed-citation xml:lang="en">Zhumadilov K. et al. Measurement of absorbed doses from X-ray baggage examinations to tooth enamel by means of ESR and glass dosimetry //Radiat. Environ.Biophys. - 2008. - Vol. 47. P. 541-545.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Toyoda S. et al., ESR Measurements of Background Doses in teeth of Japanese Residents //Radiat. Meas. - 2011. - Vol. 46. - P. 797-800.</mixed-citation><mixed-citation xml:lang="en">Toyoda S. et al., ESR Measurements of Background Doses in teeth of Japanese Residents //Radiat. Meas. - 2011. - Vol. 46. - P. 797-800.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
